Tender for Invition E Quotations For The Items Specified In The Detailed Project Report (Dpr) Regarding The Cctv System And Related Works For Making Lonavala A Smart And Safe City And Not Meintioned In Pwd Electrical Csr. , A. Cameras , Supply, Installation, Testing And Commissioning Of 5 Mp Outdoor Bullet Camera, H.264 & H.265, 1/2.8 Image Sensor, Outdoor Fixed Bullet Lens, Ir Correction, Auto Iris, Audio Capture Capability, White Balance, Backlight Compensation, Wdr, Security - Pixel Protection, Ip Address Filtering, User Access Log, Https Encryption, Nema4x / Ip66 Rated Casing, Ul/Ce/Fcc/Onvif Certification. , Supply, Installation, Testing And Commissioning Of Ptz Camera With Qhd (2560X1440) @50Fps (4Mp), 30X Optical Zoom With Autofocus, Ip66, Ik10 And Nema 4X, Ul/Ce/Fcc/Onvif Certification, H.265, Auto Day/Night, Ir Illumination 200 M. , Supply, Installation, Testing & Commissioning Of 5 Mp Outdoor Bullet Camera, H.264 & H.265 1920X1080, With Face Detection Feature, Ir Correction, Auto Iris, Audio Capture, White Balance, Blc, Wdr, Security, Ip Address Filtering, User Access Log, Https Encryption, Nema4x / Ip66 Casing, Ul/Ce/Fcc/Onvif Certification. , Supply, Installation, Testing & Commissioning Of 5 Mp Outdoor Bullet Camera With Anpr Technology, H.264 & H.265 1920X1080, Ir Correction, Auto Iris, Audio Capture, White Balance, Blc, Wdr, Ip Address Filtering, User Access Log, Https Encryption, Nema4x / Ip66, Ul/Ce/Fcc/Onvif Certification. , Supply, Installation, Testing And Commissioning Of Infrared Illuminators - Range 60-80 M, High Sensitivity At Zero Lux, Automatic On/Off, Nema 4X / Ip66, Ul/Ce/Fcc/Onvif Certification. , Pvc Hensel Make Waterproof Junction Boxes, Ip 65. , Housing Waterproof For Camera. , Supply And Fixing Outdoor Enclosure To Keep Switch, Ups, Nvr And Fiber Termination Accessories. Weather Proof Junction Box With Fan, Pvc, With 5 annual periodical maintenance Mcb. , Passive Networking (Lan / Fiber / Conduits/Cabling/Trenching) , Supplying And Installing Armoured Single-Mode Optical Fiber Cable, 12-Fiber Core, 9/125 ?m With Corrugated Steel Armour, In Pre-Installed Underground Hdpe Pipe Complete. , Supplying And Installing Armoured Single-Mode Optical Fiber Cable, 24-Fiber Core, 9/125 ?m With Corrugated Steel Armour, In Pre-Installed Underground Hdpe Pipe Complete. , Supplying And Installing Cat 6 Armoured Cable With Pvc Outer Jacket In Pre-Installed Underground Hdpe Pipe. , Supply, Installation, Testing And Commissioning Of 12 Port Liu Loaded With Sm/Sc Connectors And Adaptors With All Accessories. , Supplying And Installing Single-Mode Simplex Pigtail With Sc/Upc Connector As Per Industry Standard. , Supplying And Installing 12-Port Loaded Fiber Liu Including Pigtails And Adaptors (Single-Mode) With Required Couplers / Accessories. , Supplying And Installing Pre-Terminated Patch Panel With Best-In-Class Insertion Losses, Mounted In Pre-Installed Location As Per Specification. , [Modified] Supplying & Installing Industrial-Grade Layer 2 Managed Poe+ Switch (8-Port Min.), Extended Operating Temperature Range -40°C To +75°C, Ip30/Din-Rail Or Ip66 Enclosure Rated, For Outdoor Edge/Junction-Box Deployment Connecting Cameras To The Fiber Ring - For Hard-Core Edge Layer. , Supplying And Installing 5-Port Patch Cord Single-Mode Duplex For Od9/Os2 Complete. , Supplying And Fixing 1 M Utp Patch Cord Of Cat 6 Type In Position As Per Specification No. Wd Cdc/Pc. , Electrical / Earthing & Lightning Protection (Ups & Batteries) , Supplying And Erecting Mains With 3 X 2.5 Sq Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Trench/Conduit Including Providing Extra Wire (Flexible) As Per Specification Wd-Rm/Rm. , Supplying And Erecting Hms Pvc Conduit 25 Mm Dia. With Pvc Accessories On Side/Ceiling As Per Specification Wd-Rm/Con. , Supplying And Erecting (Excluding Excavation Up To 1 Ft Depth And Refilling With Available Soil Compacted To 95% Mod Proctor Density) Double-Wall Corrugated (Dwc) Hdpe Pipe For Laying Underground Armoured Cables / Fiber - Including Bell-Shaped Fittings, Locator Wire And Joining; Pipe Must Be Marked And Reusable. , Supply And Installation Of Ip Public Address System - 22 Ip Speakers With Amplifiers And 8 Microphones, Integrated With Cctv Surveillance Network For Smart City Public Address Per Safe City detail project report Section 2.3.7.2. , Batteries 100Ah 12 V - For Field Pole Ups Backup (One Per Edge Switch Location). , Supplying And Installing 6 Kva Online Ups With Battery Bank To Provide Minimum 30 Minutes Back-Up. , Batteries 100Ah 12 V - For Ccc Ups Bank. , Supply, Installation, Testing And Commissioning Of Maintenance-Free Earthing Comprising Electrode Of 17.2 Mm Dia. Low-Carbon Steel With 250-Micron Molecular-Bonded Copper, With Surface Enhancing Back-Fill Compound 30 Kg, Including Excavation, With Earthing Compound Around The Electrode, Suitable For Se/Wp Earth-Pit - For Ccc Building Earthing (Distinct From Field Pole/Mast Lightning Protection At Item 88). , Central Command & Control Centre (Ccc) , Supply, Installation, Testing And Commissioning Of Servers (For Vms / Analytics) With Required Compute And Storage Configuration. License. , Supply, Installation, Testing And Commissioning Of L3 Core Switches. , Supply, Installation, Testing And Commissioning Of Server (For Primary Storage / Management) With Required Configuration Including Os And Licenses. , [Modified] Supply, Installation, Testing And Commissioning Of Nas / Primary Storage, 580 Tb Usable Capacity Configured In Raid 6 (Or Raid 50) For Fault Tolerance, Built With Enterprise-Grade Surveillance/Data-Center-Class Hdds (Not Desktop-Class) - Raid Level And Drive Class Mandatory To Prevent Vendor Down-Specification. , Supplying And Fixing Ip Voice Mount Server Rack With 850 X 600 X 2070 Mm Size. , Supply, Installation, Testing And Commissioning Of Video Management System (Vms) Software Base License With Capacity To Support The Video Management System / Video Surveillance System And Ip Network. The Vms Shall Be Capable Of Unified Management Of Ip Based Cameras, Video Analytics Modules, Nvrs, Sensors And Other Vms Components On A Centralised Platform; Supports Up To 200 Cameras Per Server (Scalable To 1000+); Supports Unlimited Number Of Cameras Across Multiple Servers; Supports Unlimited Number Of Clients/Users; Provides H.264 / H.265 Decoding; Per-Camera License Required. , Vms Software Including 4 Channels For Client Viewing. , Enterprise Vms: 200 Camera Licence (Covering All 350 Field Cameras + 4 Indoor Ccc Cameras = 354, Rounded To 400 With Buffer For Expansion). , Enterprise Vms: 10 Camera Video Analytics Licence • Video Analytics In Live View For 10 Cameras • Advanced Ai-Based Object Classification (People / Vehicle / Bag Detection). , Enterprise Vms: 40 Camera Automatic Number Plate Recognition Licence - Per Safe City detail project report Section 2.3.3 (Police Department Estimated Requirement Of About 40 Anpr Cameras At Octroi Nakas & Key Junctions). , Enterprise Vms: 10 Simultaneous User Licence. , Virtual Software License Dongle For Matrix Licenses. , Network Ptz Controller With 4D Joystick. , 5Mp Ir Dome Camera (2.8Mm Lens With Aperture Of F1.6 (By Default)/F2.0 (On Demand)), Audio Support. , Surge Protection Device (Spd). , Aspirating Smoke Detection Cr. , Heat Detector. , Co2 Fire Extinguisher. , Abc Dry Powder Extinguisher. , Workstations, Ups, miscellaneous Ccc Equipment , Supply, Installation, Testing And Commissioning Of Hid Access Control Reader With Inbuilt Controller. , Supply, Installation, Testing And Commissioning Of Em Lock Single Door. , Supply, Installation, Testing And Commissioning Of Glass Break Sensor. , Supply, Installation, Testing And Commissioning Of Em Lock Single Door (Additional). , Supplying & Erecting 55 Professional Lcd Display 1920X1080 Full Hd, Otherwise Same Specs As Above - Complete As Per Cctv-Mon Specifications. , Supplying & Installing Standard Rack-Mount Workstation Pc With Operating System, Monitor And Accessories For Vms Operator Console. , Supplying & Installing Cat 6 Fence-Mounted Patch Panel Complete As Per Wd-Dc Specification. , Supplying And Installing 3-In-1 Four-Pair Patch Cord Double Single-Mode For Od/2 Complete. , Supplying And Installing 1U Din Hdmi Connection Complete, 1 M Or As Per Length Required At Site. , Supplying And Installing 1U Hdmi Connection Complete (Additional). , Control Room / Ccc Infrastructure - Video Wall, Hvac, Power Backup & Compliance , Supply, Installation, Testing And Commissioning Of Video Wall Led Display Cube, 55 Diagonal, Ultra-Narrow Bezel (=0.88 Mm), =500 Cd/M² Brightness, 1920X1080 Resolution Per Cube, 24X7 Duty Rated Panel, Front-Serviceable, With Mounting Frame - For Control Room Video Wall. , Supply, Installation, Testing And Commissioning Of Video Wall Controller / Processor, Modular Chassis, Min. 16 Input Ports (Hdmi/Dp/Sdi/Ip), Supports 4K Decode, Seamless Source Switching, Redundant Power Supply. , Supply And Erection Of Video Wall Floor-Standing / Wall-Mounted Support Structure With Integrated Cable Management, Sized For 12-Cube Array. , Supply And Installation Of Video Wall Content Management Software License - Multi-Source Layout Management, Drag-Drop Windowing, Scheduling. , Supply And Installation Of 27 Full Hd Led Operator Monitor, For Multi-Monitor Vms Workstation (Additional To Primary Display). , Supply And Installation Of Dual-Monitor Adjustable Desk-Mount Arm. , Supply, Installation, Testing And Commissioning Of Kvm Switch, 4-Port, Multi-Pc Single-Console Access. , Supply And Installation Of Ergonomic Control-Room Operator Console/Desk With Integrated Cable Management And Monitor Mounting Rail, 24X7 Duty Rated. , Supply Of Ergonomic 24X7-Duty Operator Chair With Lumbar Support And Castors. , Supply And Installation Of Supervisor / Shift-In-Charge Desk. , Supply And Installation Of 42U Server Rack (800 X 1000 Mm) With Front Glass Door, Pdu Mounting Rails And Cable Manager, In Addition To Existing Ip Voice Racks. , Supply And Installation Of Rack-Mounted Metered Pdu, 32A, 20-Outlet. , Supply And Installation Of Rack Cooling Fan Tray, Thermostat-Controlled. , Supply, Installation, Testing And Commissioning Of Precision Air-Conditioning (Pac) Unit, Close-Control Type, 5.5 Tr, For Server Room - N+1 Redundant Configuration. , Supply, Installation, Testing And Commissioning Of Split Ac, 2 Ton, Inverter, For Control-Room Comfort Cooling. , Supply And Installation Of Server-Room Temperature & Humidity Monitoring System With Sms/Email Alerting. , Supply, Installation, Testing And Commissioning Of Diesel Generator Set, Silent/Acoustic Enclosure, 30 Kva, With Amf Panel, For Extended Power Backup Beyond Ups Runtime. , Supply And Installation Of Automatic Mains Failure (Amf) / Automatic Transfer Switch Panel. , Supply, Installation, Testing And Commissioning Of Online Ups, 20 Kva, N+1 Configuration, Min. 30-Min Backup, Dedicated To Ccc Critical It Load (Servers, Vms, Video Wall). , Supply, Installation, Testing And Commissioning Of Ntp/Gps-Based Time Synchronization Server, For Evidentiary Timestamp Accuracy Across Vms/Nvr/Servers. , Supply, Installation, Testing And Commissioning Of Clean-Agent (Fm200 / Novec 1230) Fire Suppression System For Server Room, Including Cylinder Bank And Release Panel. , Supply And Installation Of Addressable Fire Alarm Control Panel For Ccc Building. , Supply And Installation Of Raised/Access Flooring For Server Room, Per Sqm. , Supply, Installation, Testing And Commissioning Of Internal 5Mp Dome Camera For Control-Room Self-Monitoring. , Testing, Commissioning, Operator & Administrator Training, And Preparation Of As-Built Documentation / O&M Manuals For The Complete Ccc. , Civil Works Additions - Right-Of-Way, Hdd & Lightning Protection [Round 2] , Horizontal Directional Drilling (Hdd) For Fiber/Power Duct Road Crossings - Boring, Casing Pipe And Surface Reinstatement, For Stretches Where Municipal Authority Prohibits Open Trenching On Major/Newly-Paved Roads. , Road Restoration - Asphalt Resurfacing To Original Municipal Road Specification After Open Trenching. , Road Restoration - Concrete/Paver-Block Restoration (Footpaths, Medians, Junctions) After Open Trenching. , Maintenance-Free Earthing Pit With Spike-Type Lightning Arrestor, Down-Conductor And Test Link - One Per Field Pole/High-Mast, For Direct-Strike And Induced-Surge Protection (Distinct From Ccc Building Earthing At Item 30). , Networking & Cybersecurity Hardening [Updated - Round 3: Nms & Backup Software Added Per Safe City Dpr] , Industrial-Grade 1G Sfp Optical Transceiver Module, Extended Temperature Range (-40°C To +75°C), For Edge Poe+ Switch Fiber Ring Uplinks (2 Per Switch × 110 Switches, Redundant Ring Pair, Rounded). , Industrial-Grade 10G Sfp+ Optical Transceiver Module, For Core L3 Switch Fiber Uplinks. , Next-Generation Firewall (Ngfw) / Unified Threat Management (Utm) Appliance With Built-In Ips, Application Control, Vpn Concentrator, Anti-Malware, Web Filtering And 3-Year Threat-Intelligence Subscription - Deployed As Ha Pair At Ccc Network Core To Secure Internet-Facing Links (Remote Alerts, Vip Viewing, Cloud Backup). Ips/Ids Functionality Is Integral To This Ngfw Appliance (No Separate Ips Line Item Required). , Supply, Installation, Testing And Commissioning Of Enterprise Network Monitoring System (Nms) Software With Snmp V2c/V3 Support, Auto-Discovery Of All Network Devices (Switches, Routers, Firewalls, Cameras, Servers, Ups), Real-Time Topology Mapping, Bandwidth/Utilization Monitoring, Fault Alerting (Sms/Email/Snmp Trap), Sla Dashboard With Uptime/Performance Metrics Per Safe City detail project report Sla Monitoring Requirement, Historical Reporting And Audit Trail, 3-Year Software Subscription - Per Lonavala Components Scope (Nms Application) And Safe City detail project report Section 4 (Sla Measurement Tools To Be Supplied By Si). , Supply, Installation, Testing And Commissioning Of Enterprise Backup & Recovery Software With Agent-Based And Agentless Backup Support For All Servers (Vms, Analytics, Ad, Management), Nas/Storage, And Database; Features Deduplication, Incremental/Differential Backup, Image-Level Backup, Bare-Metal Restore, Encryption At Rest And In Transit, Automated Backup Policy Per Safe City detail project report Section 2.3.8 (Information Security Policy Including Backup Policies); Dr Replication To Secondary Site; 5-Year Software Subscription. , Software Licensing & Storage Hardening [Round 2] , Linux Enterprise Server Subscription (Rhel / Ubuntu Pro Or Equivalent), 1-Year Renewable, For Vms/Analytics Edge Servers (Item 31). , Windows Server Standard License (16-Core), For Ccc Primary-Storage/Management Servers (Item 33) And Active Directory Domain Controller. , Enterprise Endpoint Antivirus / Edr License, Per Node, 5-Year Term - For All Operator Workstations And Servers (60 Vms Servers + 8 Management Servers + 2 Ad Servers + 1 Av Server + 8 Workstations = 79 Nodes, Rounded To 80). , Lto-9 Tape Autoloader, 8-Slot, Min. 400 Tb Native Capacity, For Long-Term Evidentiary Archival Beyond Primary/Secondary Storage Retention Window. , Lto-9 Tape Cartridge, 18 Tb Native Capacity - Initial Stock For Archival Rotation. , K. Safe City Additions - Dr, Smart City Components, Analytics & Compliance [New - Round 3] , Supply, Installation, Testing And Commissioning Of Internal Firewall (Ha Pair) For Trusted-Zone Segmentation Between Data Center Lan Tiers (Vms/Analytics Tier, Database Tier, Management Tier) - Per Safe City detail project report Data Center Architecture (Internal Firewall Distinct From External Ngfw). , Supply, Installation, Testing And Commissioning Of San Switch, 16-Port Fibre Channel (16 Gbps), For Connecting Application Servers And Database Servers To Shared Storage - Per Safe City detail project report Data Center Architecture (San Switch + San Box Shown In Database Tier). , Supply, Installation, Testing And Commissioning Of Antivirus / Edr Management Server (Dedicated), Centralized Management Console For Endpoint Protection Policy Distribution, Real-Time Threat Detection, Quarantine, And Patch Management Across All Workstations And Servers - Per Safe City detail project report Data Center Architecture (Antivirus Server Shown In Dmz). , Supply, Installation, Testing And Commissioning Of Active Directory / Directory Server (Dedicated), For Centralized User Authentication, Rbac, Group Policy Management, And Audit Logging Across The Surveillance Network - Per Safe City detail project report Data Center Architecture (Directory Server Shown In Trusted Zone). , Supply, Installation, Configuration And Commissioning Of Sla Monitoring & Helpdesk Management Software With Automated Sla Tracking, Trouble Ticketing, Incident Management, Escalation Matrix, Performance Dashboards, And Audit Reporting - Per Safe City detail project report Section 4 (Si To Supply Software/Automated Tools To Monitor All Slas; Helpdesk As Single Point Of Contact For Complaint Management). , Supply, Installation, Testing And Commissioning Of Dr Site Storage (Replication Target), 290 Tb Usable Capacity, Configured As Secondary Storage For Disaster Recovery Replication From Primary Nas Via Backup Software - Per Safe City detail project report Section 2.3.3 (Dr Site For Data Back-Up, Preferably Within Cp Office / City Office). , Supply, Installation, Testing And Commissioning Of Emergency Call Box (Ecb) System - Single-Button Digital Transceiver, Connects To Police Department Over Existing Cctv Network, Weatherproof Ip66 Enclosure, Integrated With Junction Box/Camera Pole - Per Safe City detail project report Section 2.3.7.1 (Approx. 10 Locations, Placed At Police/Traffic Islands Or Pedestals). , Supply, Installation, Testing And Commissioning Of Variable Message Sign (Vms) Display - Outdoor Led Display Board, Ip66, Ethernet Connectivity, Remote Content Management For Traffic Alerts, Public Information, And Emergency Notifications - Per Safe City detail project report Section 2.3.7 (Smart City Component, Approx. 10 Locations). , Supply, Installation, Testing And Commissioning Of Ruggedized Outdoor Wifi Mesh Access Point, Ip67, Extended Temperature -40°C To +65°C, Dual-Band 802.11Ac/Ax, For Last-Mile Wifi Mesh Connecting Cameras And Smart City Sensors To Junction Box - Per Safe City detail project report Section 2.3.2 (Wifi Mesh At Last Mile, 2 Ports Per Switch/Router For Smart City Components). , Supply, Installation, Customization And Commissioning Of Gis Software & Customized Dashboard - Geographic Information System Integration With Vms For Camera Location Mapping, Incident Visualization, Zone-Based Analytics, And Role-Based Custom Dashboards For Various Personnel Categories - Per Safe City detail project report Section 2.3.3 (Gis And Customized Dashboard As Key Components Of Application Portfolio). , Supply, Installation, Configuration And Commissioning Of Collaborative Monitoring Integration Software - Enables Ingestion Of Video Feeds From Approx. 20 External Public/Private Establishment Cctv Systems, Citizen Video Upload Via Mobile App With Otp Authentication, And Continuous Streaming On Video Wall Cube - Per Safe City detail project report Section 2.3.5 (Collaborative Monitoring Framework). , Supply, Installation, Testing And Commissioning Of Police Van Mobile Surveillance Kit - Includes 1 Laptop (18.5 Screen) For Local Viewing, 2 Outdoor Fixed Box Cameras, Local Storage For 16 Hours, 1 Full Hd Handheld Camera With Wifi Streaming Capability, Mounting Accessories, Cabling, Installation And Training - Per Safe City detail project report Section 2.3 (Mobile Surveillance On Police Vehicles, 3 Nos.). , Iso 27001 Certification Audit, Information Security Policy Preparation, And Compliance Documentation For The Cp Office Control Center - Per Safe City detail project report Section 2.3.8 (Si To Prepare Information Security Policy Within 1St Quarter Of Fat; Obtain Iso 27001 Certification Within 2 Quarters Of Fat; Payment Withheld Till Certification Obtained).
|