Medical Oxygen 99%, Colorless And Odorless Gas, Contains Not Less Than 99% By Volume Of Oxygen, Gas Or Gas Mixture Intended To Come In Direct Contact With The Human Organism For The Purposes Of Diagnosis, Treatment Or Prophylaxis, 3M³, 7M³ Cylinders , 10M³ Or 12M³ (With A Variation Of 1M³) Of Medicinal Oxygen, And The Cylinder Is Made Available On Loan By The Company That Will Provide The Gas Load, Medicinal Oxygen 99% Ppu, Gas Or Mixture Of Gases Intended To Come Into Direct Contact With The Human Organism For Diagnostic Purposes, 1M³ Cylinder (With Variation Of 1M³) Of Medical Oxygen Transportable By The Patient. Transportable Medical Oxygen For Use By Samu, Rental Of Medical Oxygen Concentrator - Capacity Of 0.5 To 5 Liters Per Minute Of Therapeutic Oxygen For Home Care; - With Oxygen Purity Indicator System; - Filters For Removing Dust, Bacteria And Other Particles; - With Low Electrical Consumption, Easy Maintenance, Maximum Noise Level Of 50Db; - Performance: 0.5 To 5 Lpm Between 90% And 96%; - With Alarms For Power Outages, High Pressure And Low Pressure; - With Flowmeter; - With Carrying Handle; - With Casters On The Feet; - It Must Be Accompanied By 01 (One) Humidifier Cup, 01 (One) Silicone Nasal Catheter, And With An Extender Of At Least 2 Meters; - Electrical Supply, With Monthly Energy Consumption Between 300-400W. Units Must Be Made Available For The 220/230V/60Hz Network. - It Must Come With A Cylinder With Autonomy Of 08 (Eight) Hours Per Recharge, For Use In The Event Of An Equipment Breakdown Or Lack Of Electrical Power. - Cylinder Support, Installation And Uninstallation Of Kit For Oxygen Therapy In Oxygen Cylinders, With Supply Of Accessories On Lease Regime, Provision, Installation And Uninstallation Of High Pressure Regulating Valve With Flowmeter And Humidifier For Medical Use, Chrome Metal Valve, With High Pressure Manometer, With Scale From 0 To 300Kgf/Cm², Inlet With Sintered Bronze Filter, Fixed Pressure Of 3.5Kgf/Cm², With Safety Valve, 0-15 Lpm Female Flowmeter, Providing Gas Flow Data In Liter Per Minute, Working Pressure Within The Range Of +/- 3, Body In Chromed Brass, Polycarbonate Bottles: Stainless Steel Ball, Nut/Butterfly: In Green Nylon (Abnt Standard) And Chrome Button Outlet Nipple, Humidifier 250Ml, With Nylon Lid, As Specified, Tube With Bubbler To Allow Particles To Be Dragged, Translucent Cup With Minimum And Maximum Level Indication. Note: The Equipment Must Be Installed In The Homes Of Patients Who Use Oxygen Therapy And In The Health Units Of Navegantes/Sc., Supply And Installation Of A Silicone Probe And Nasal Cannula, With A Length Of At Least 2 M, Made Of Silicone Or Pvc Transparent, Non-Toxic, Sterile, In The Form Of A Straight And Solid Cylinder, Distal End Duly Finished And Fixed To The Connector Device, Catheter Capable Of Maintaining Stable Attachment To The Oxygen Conductor Tube Registered With The Ministry Of Health, Compressed Air Cylinder (8M³ Capacity)
|