Portable Ultrasound: Fully Digital Portable Ultrasound Equipment For High Performance Applications In General/Internal Medicine, Abdominal, Vascular/Venous, Adult Cardiac, Pediatric And Neonatal, Musculoskeletal, Gynecological/Obstetric, Etc. Equipment Should Not Exceed 9 Kg With Transducer And Battery Installed;Picture Mode:2D Picture Mode; Automatic Image Optimization In 2D Mode; M Mode; Doppler: Pulsed, Continuous And Tissue; Color Doppler And Color Power Doppler; Calculations And Data Display; Duplex; Tissue Harmonic Image; View Modes: Control Panel With Easy Interface Controls, With Extended Alphanumeric Keyboard. Image Acquisition And Processing: Minimum Scale Of 256 Gray Levels; Viewing Modes: Real-Time Zoom; Cineloop With At Least 1100 Frames; User Interface: Lcd Monitor With Minimum Diagonal Of 15 With Angle Adjustment; Control Panel With Controls Grouped By Application; W/Extended Alphanumeric Keyboard; Anti-Splash Keyboardimage Storage: Internal Storage Memory Of At Least 500 Gb; Usb Input;Connectivity:Export Of Images In Formats Compatible With Pc; At Least Two Usb Ports; Audio Output; Integration Of Hdmi And Wifi Connections Directly Into The Equipment; Transducers: 01 Linear Transducer In The Frequency Range Of 6 To 13 Mhz ± 1 Mhz For Vascular Applications With The Possibility Of 1 Mhz Up Or Down; 01 Sector Transducer In The Frequency Range Of 1 To 5 Mhz ± 1Mhz For Cardiac Applications With The Possibility Of 1 Mhz Up Or Down. 01 Convex Transducer In The Frequency Range Of 2 To 5 Mhz ± 1Mhz For Obstetrics, Gynecology And Abdominal Applications. Notes: Transducers Must Be Multifrequency And Broadband; Selectable In 2D Mode; Transducers Capable Of Using Image Modes: B Mode, M Mode, Color Doppler, Pulsed Doppler, Continuous Doppler. The Equipment Must Be Upgradable, Allowing Other Transducers And... To Be Purchased In The Future, Horizontal Autoclave Of At Least 100 Liters; Being Digital; Voltage 220 W; Be Made Of Stainless Steel; Thermal Insulation; Programmable Microprocessor. Possibility Of Programming Time, Drying And Cooling; Closed Door Drying; Adjustable Temperature Above 121 Degrees; Being Saturated Steam Under Pressure; Dry: Plastic Materials, Rubber, Surgical Instruments, Glass And Liquids; It Is Possible To Control Quality Through Tests, Such As Bowie & Dick And Others; The Opening Door Can Be Guillotine (Vertical Elevation) Or Hatch (Central Steering Wheel) Temperature And Pressure Sensors; Possibility Of Steam Generator; Litration Above 100 L; Meet The Requirements Of Anvisa And Nr 10, 12, 13; Regarding Size, This Should Be As Small As Possible, As Long As It Meets These Specifications. Warranty From 5 To 15 Years, If Possible; Training For The Hnsn Team; Easy-To-Call Technical Assistance., Gas, Ph, Electrolyte And Metabolic Analyzer - Gt Portable -*Measured Parameters: Ph, Po2, Pco2, Hct, Na, K, Ca, Cl, Lac, Glic *Calculated Parameters: H+, Hco3 , Hco3- Std, Be, Beecf, Tco2, Bb, P50, So2%, Shunt, Thb, A-Ado2 And O2ct. Technical Features: Built-In Thermal Printer Ease Of Operation Does Not Use Electrodes, Does Not Use Gases For Calibration. Minimum Volume Sample: 100 L Syringeelectrical Characteristics: Voltage: 110 Or 220 Vanalysis Time 60 Seconds. Mains Frequency 50 Hz - Power 50 Va - Maximum
|