Tenders Are Invited For Miscellaneous Medical Devices And Products – Open Procedure For The Supply Of Medica ...
Tender Notice
TenderID
78512493
Tender Brief
Tenders Are Invited For Miscellaneous Medical Devices And Products – Open Procedure For The Supply Of Medical Devices For The U.O.C. P.O. Pain Therapy San Giuliano – Asl Napoli 2 Nord
Miscellaneous Medical Devices And Products – Open Procedure For The Supply Of Medical Devices For The U.O.C. P.O. Pain Therapy San Giuliano – Asl Napoli 2 Nord. Fully Implantable Neurostimulator For Peripheral Nerves With External Stimulator With Wifi Connection,Kit For Intraforaminal Radiofrequency - Connectable To A Generator Able To Deliver Randomized Radiofrequency According To The Sluijterteixerapoisson Protocol, Comprising A 100Mm Needle With Bluten Tip And Blunt, Thermocouple, Needle-Introducer Cannula And Dispersion Plate - See Description Of Lot 2 Of The Fa Need,Intrarticular Radiofrequency Kit Connectable To A Generator Able To Deliver Randomized Radiofrequency According To The Sluijterteixerapoisson Protocol, With The Possibility Of Choice Between Hybrid Electrodes (Thermocouple Integrated Into The Cannula) And Electrodes To Be Composed (Thermocouple And Cannula Not Integrated) - Ve Dasi Description Batch 3 Of The Requirement,Sphenopalatin Ganglion Block Kit - Integrated To Perform The Block Of The Sphenopalatine Ganglion Transnasally Including Right/Left Orientable Nasal Applicator And Graduated Syringe With 0.3 Ml Injection Block And Non-Woven Preparation Cloth,Patch For High Frequency Percutaneous Neuromodulation - Percutaneous High Frequency Neuromodulation System For The Management Of Chronic And Acute Pain - See Description Of Batch 5 Of The Requirements,Hydrogel For Severe Gonarthrosis Class Iib Device, Composed Of Transparent, Non-Absorbable, Bio-Compatible Hydrogel, Injectable For Intra-Articular Injection, Made Up Of 2.5% Cross-Linked Polyacrylamide And Water With 97.5% Pyrogen. - See Description Of Lot 6 Of The Requirements,Rf Patch Kit With Procedural Set Rf Patch Kit Including Antenna Capable Of Using A Pulsed Rf Electric Field Via A Small Generator Inside The Patch That Can Be Activated By The On/Off Button, The Duration Of The Generator Is Approximately 7 Days With Use H24.- See Description Of Lot 7 Of The Requirements,Sterile Single-Use Kit For The Treatment Of Intra-Extra Foraminal Hernias By Endoscopy With Single-Lateral Access. - See Description Of Lot 8 Of The Requirements,Gangliar Stimulation - Fully Implantable Pulse Generator For The Selective Stimulation Of The Dorsal Root Ganglium With At Least 16 Contacts, With The Possibility Of Managing At Least Four Leads. - See Description Of Lot 9 Of The Requirements,Electronic Implantable Pumps - Intrathecal Pump With Anti-Overpressurization Valve And Antibacterial Filter (0.22 Micron), Power Supply With Long-Lasting Lithium Battery, Equipped With Battery Exhaust And Drug Exhaust Alarms, Which Allows The Administration Of The Drug In Continuous Fusion ,...- See Description Of Lot 10 Of The Requirements,Cannula For Subcutaneous Stimulation - Needle Kit Electrode Certified For The Pens Therapy Neurostimulator System For The Stimulation Of Peripheral Nerve And Peripheral Nerve Terminations And Certified For The Stimulation Of The Single Nervous Target - See Description Of Batch 11 Of The Requirement,4 Fr Multifunctional Neurostimulators-Lead Catheters For Pharmacological Treatments And Pulsed Radiofrequency At 42 °C For Neuromodulation Of Nervous Tissues, In Monopolar Or Bipolar Mode - See Description Of Lot 12 Of The Requirements
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 78512493
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.