Laboratory Building Construction Work – 24E40078; Laves House 1, Braunschweig; House 1, Replacement Building; Insulation Work. Delivery And Assembly / Installation Of 2,100 M Of Elastomer Foam Cold Insulation (Insulation Thickness 13 Mm) On Drinking Water Pipes Made Of Stainless Steel Pipes, Up To Dn 65, Inclusive. Fittings And Connecting Pieces As Well As Fittings, Suspensions, In Small Parts With Hard Plastic Film, Laying In The Building; 840 M Of Elastomer Foam Cold Insulation (Insulation Thickness 13 Mm) On Service Water Pipes Made Of Stainless Steel Pipes Up To Dn 50, Inclusive. Fittings And Connecting Pieces As Well As Fittings, Suspensions, In Small Parts With Hard Plastic Film, Laying In The Building; 3,000 M Of Elastomer Foam Cold Insulation (Insulation Thickness 19 Mm) On Cold Pipes Made Of Steel Pipes Up To Dn 200, Inclusive. Fittings And Connecting Pieces As Well As Fittings, Flanges, Pumps, Heat Exchangers, Cold Distributors, Buffer Storage, Suspensions, In Small Parts With Mechanical Protection Made Of Sheet Metal Jacket, Laying In The Building; 3,300 M Of Mineral Wool Thermal Insulation (Insulation Thickness According To Geg) On Heating Pipes Made Of Steel Pipes Up To Dn 80, Inclusive. Fittings And Connecting Pieces As Well As Fittings, Suspensions, In Small Parts With Hard Plastic Film, Laying In The Building; 5,800 M² Of Mineral Wool Thermal Insulation (Insulation Thickness 30 Mm) As A Slatted Mat On Rectangular Ventilation Ducts Made Of Galvanized Sheet Steel, Edge Length Up To 2,000 Mm, Inclusive. Fittings And Connecting Pieces As Well As Doubling, Laying In The Building; 1,700 M Of Mineral Wool Thermal Insulation (Insulation Thickness 30 Mm) As A Slatted Mat On Round Ventilation Pipes Made Of Galvanized Sheet Steel, Up To Dn 355 Inclusive. Fittings And Connecting Pieces As Well As Doubling, Laying In The Building; 450 M² Of Elastomer Foam Cold Insulation (Insulation Thickness 19 Mm) On Rectangular And Round Ventilation Ducts Made Of Galvanized Sheet Steel, Edge Length Up To 2,000 Mm, Inclusive. Fittings And Connecting Pieces As Well As Doubling, Laying In The Building; 164 Pieces Of Fire Protection Insulation On Sanitary Pipes Made Of Stainless Steel Pipe With Cold Insulation Up To Dn 65, Laid In The Building; 226 Pieces Of Fire Protection Insulation On Heating Pipes Made Of Steel Pipes With Thermal Insulation Up To Dn 80, Laid In The Building; 212 Pieces Of Fire Protection Insulation On Stainless Steel Pipelines For Technical Gases Up To Dn 40, Laying In The Building; Close 50 Wall Openings With Concrete (Work On Ventilation Components And Cooling Pipes), Laying In The Building; 280 M² Air Duct In E-90 Quality And As U-Shells Made Of Calcium Silicate Plates On Ventilation Pipes And Air Ducts Made Of Galvanized Sheet Steel, Laid In The Building; 88 Pieces Of Fire Protection Insulation On Cold Pipes Made Of Steel Pipes With Cold Insulation Up To Dn 200, Laid In The Building; 220 Kg Of Fire Protection Mortar For Closing Openings On Pipes, Laying In The Building; 44 Pieces Of Fire Protection Insulation On Cable And Pipe Systems As Mineral Wool Panels - And As Mortar Insulation Up To 2 M², Laying In The Building.
|