Tenders are invited for Announcement of Tendering for Medical Equipment Procurement Project of Sports Vocational CollegeBudget 3847800 yuan Package 1 Contract package budget 1667800 yuan Bid deposit 33356 Meta procurement requirements including but not limited to the name quantity brief technical requirements or service requirements of the subject etc 1 Standard configuration 12 wet and hot compresses 2 Constant temperature control set temperature range 18 3 73 8 thermal protection device to prevent equipment from overheating 3 Drainage system better than similar products 4 Exclusive for original factory supporting Hot and humid compress pack 5 Equipped with vinyl coated stainless steel drying rack in the device place the heat pack to keep the pack dry and flat 6 Large size mobile hot pack equipment with lock and thermometer 7 Equipped with 4 casters treatment process It can be moved flexibly quiet and no noise 8 Two of the casters can be locked to prevent the device from sliding the temperature control button at will 9 It is used for the rehabilitation of muscle soreness arthritis and other diseases It is suitable for pedicure hand therapy sports training physics Treatment occupational therapy chiropractic treatment hydrotherapy household consumption long term care etc 10 Power supply 115V 3Amp 11 Water tank volume 60L 12 Size 406mm 610mm 813mm 13 Recyclable stainless steel welded solid and environmentally friendly 14 Bottom arch design easy to clean and maintain 15 The switch is equipped with an indicator light and the light is on when the equipment is working 16 The heat pack can be evenly circulated and heated during the treatment process for up to 30 minutes 17 100 cotton fabric is sewn with tough nylon thread soft and comfortable Sturdy and durable 18 Thermotherapy cloth bag durable Velcro lining clean and hygienic easy to clean and reuse Configuration 1 1 host computer 2 1 power cord 3 1 copy of the manual 4 12 electrocardiographs 12 leads for wet and hot compresses 1 Standard 10 electrode synchronous collection and synchronous recording The original machine has a built in integrated printer And print twelve ECG waveforms simultaneously The specifications for ECG drawings 210 140 2 Support 12 lead and 18 lead recording 3 High definition color LCD display 3 1 Screen size 7 display resolution 800 480 3 2 Display 12 lead ECG waveform on the same screen the display duration of the same screen is 5s 3 3 The screen can be folded 0 100 degrees stepless adjustment multi angle observation 4 Full keyboard support Chinese input 5 Common mode rejection ratio 100dB analog to digital conversion accuracy 2 5 V frequency response 0 05Hz 150Hz 0 4 3 dB 6 ECG analysis program 6 1 ECAPS 12C automatic measurement and analysis algorithm which can analyze the heart for up to 24 seconds Electric waveform 5 categories of judgment conclusions more than 200 kinds of analysis conclusion suggestions analysis conclusions are coded in digital form for easy query 6 2 Supports independent analysis of the right chest posterior wall leads and 18 lead ST Map output 6 3 The analysis results support Chinese and English switching can include explanations of reasons and the display and printing languages can be set separately and support two versions of Minnesota code 6 4 Analysis results support screen display 7 Noise detection dual mode simultaneous dot and dash thermal mark printing 8 Automatic measurement parameters including heart rate PR interval QT QTc P QRS T electric axis RV5 SV1 voltage Equivalent Storage and transmission Built in 400 electrocardiograms support expansion 9 number of recording channels 3 3 1 6 12 channels 12 610 ECG input impedance 50MO sampling rate 8000 Hz 8Ch polarization resistance Voltage 550mV 11 Gain sensitivity selection 1 25 2 5 5 10 20mm mV12 manual or automatic or more digital filter low pass filter 75Hz 100Hz 150Hz three gears EMG filter 25Hz 35Hz two gears AC filter 50Hz or 60Hz baseline suppression filter strong weak two gears 13 paper speed 10 12 5 25 50mm S time constant 3 2 seconds 14 Print data The noise detected by the electrode is required to be displayed on the screen and the noise level is printed on the report with a solid line or a dotted line Printable program model version date and time paper speed sensitivity lead name filter status patient information ID number age gender electrode detection noise timing mark event mark ECG Waveforms analysis reports etc 15 Recording mode automatic or manual automatic recording supports real time or retrospective recording with automatic detection and prolonged recording of arrhythmia waveforms and supports automatic start of recording the recording waveform time can be adjusted between 10 24 seconds Waveform freeze recording mode duration 180s16 rhythm recording choose any 1 lead or any 3 lead 1 minute long term rhythm recording abnormal ECG can automatically or manually lengthen the recording of rhythm leads 17 support two step experiment RR interval check post exercise check with automatic analysis function 18 Network function comes with LAN interface supports wired and wireless networks The wireless network configuration requirements can be set and read in the host system settings and the communication settings can choose the SD card storage type 19 It has the function of printing grid on non grid paper 20 Synchronous signal input and output interface two 3 5mm stereo signal interface support the output of ECG synchronization signal and input and display the signal of external equipment 21 USB interface The original machine has 2 USB interfaces which simultaneously supports barcode and magnetic card readers which is convenient for doctors to operate and reduce the error input of patient information Opportunity the system settings can be read and configured with barcodes and magnetic card readers supporting LAN or wireless LAN 22 Input and output analog signal output 0 5V 1mV 5 output impedance 100O the electrocardiograph will not be damaged when the output is short circuited input key the key position supports direct input of patient ID number gender and age group special fast input Key 23 SD card interface The original machine has an SD card interface to support SD memory cards and realize large capacity storage of information The original machine can be connected to an SD wireless network card to realize mass storage and wireless network communication functions 24 Abnormal ECG can automatically or manually lengthen the recording of rhythm leads 25 Measurement parameter QTc algorithm 4 optional QTc calculation method can be read and set through system settings 26 The instrument has a protection function The standard lead wire is equipped with a defibrillation protection circuit The screen saver can be entered if the instrument is not operated for 5 minutes If the electrode falls off it can alarm the LCD display can display the electrode off part and the high frequency noise can alarm After the recording paper is used up it will automatically stop paper feeding and alarm The device supports automatic detection and intelligent helper programs 27 Measurement analysis The automatic measurement and analysis algorithm of Asian ethnographic electrocardiogram database standard is adopted and conforms to the latest international electrical safety standard IEC60601 2 51 to ensure more ideal signal accuracy validity of analysis results and patient safety Passed the national analytical electrocardiograph standard YY 0782 28 The device comes with a portable handle and comes standard with nickel metal hydride batteries The weight of the device 4 2Kg Configuration 1 recording paper 12 thermal print head cleaning pen 13 input checker 14 lead wire 15 extremity electrode 16 suction electrode 27 battery 18 technical manual 19 ECAPS 12C analysis manual Chinese version CD 110 18 Induction analysis manual 11 Treatment source 1 1 Treatment light source halogen light source 1 2 Light source output power 750W 1 3 Effective treatment band 560 1400nm 1 4 Treatment depth 10cm1 5 Irradiance 330mw cm21 6 Optical density output 1200 mW cm2 2 Heat dissipation device 2 1 Air cooling 2 2 Applicable time limit of heat dissipation device 5000H3 Support system 3 1 Universal wheel movement 3 Lifting 19 safety triple insurance anti theft bar password protection Kensington lock 20 simple user interface shortcut menu 21 wall screen function 22 user defined logo 23 automatic shutdown no signal or set time 24 Code lock function 25 automatic shutdown 26 fast automatic search of signals 27 passed the China National Compulsory Product Certification 1 Flow meter two way digital turbo type can be used permanently Flow range 0 16L Ventilation range 4 300L min Accuracy 3 Flow rate resistance 0 7cmH2O L S 14L S2 oxygen analyzer accuracy 0 02 oxygen analyzer range 0 100 3 carbon dioxide accuracy 0 01 carbon dioxide range 0 12 4 Host receiving function The latest technology Bluetooth telemetry receiving function non old fashioned radio reception is easy to be interfered 5 Host storage capacity Built in 512MB storage capacity up to 2 048 000 breaths and expandable 32G SD card storage Use 6 Rechargeable battery A new generation of rechargeable battery small in size built in the main body of the exercise cardiopulmonary tester detachable and can be used continuously for 4 hours 7 Face mask Flow rate range 0 200L S Ventilation range 10 2500L min 8 Each oxygen battery service life can be used continuously for 12 months 9 Measurement method One breath method 10 comes wi
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 31916933
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.