Contract notice Electrical Fitting WorkLE 17101 Reconstruction and expansion of Leonberg Hospital cafeteriaDescription Tendering scope KG 440 u 450 The following services are advertised a b AV SV electrical installation circuit distributor c basic and safety lighting d e f Fire alarm system for cable line routes h Transmission networks for data and telephony fire protection The General Technical Contractual Conditions for Building Services VOB Part C are used All services described in the course are to be offered ready for operation including all accessories The following are not part of the tenders a b Active components for data and telephony on site power lighting c Disassembly and dismantling work of low voltage installation systems Two new circuit distributors are planned The first is used to accommodate the final circuits that are connected to the AV network the second for the final circuits of the SV network The SV supply of safety relevant consumers and other SV consumers must be set up separately The structure of the individual distributions is shown in the appendices Depending on the use the supply is made from the distributions NSHV Kern AV and NSHV Kern SV of the Leonberg Hospital The supply is via existing cable routes from the 2nd basement of the KH to the 1st basement and from the storage area south wing 1st basement via the media channel to the technical room of the cafeteria building The contractor has to investigate the exact path of the existing stock Necessary RCDs DIN VDE 0100 410 are generally implemented as type A The residual current is 30 mA Light and socket circuits are protected separately The sub distributors are provided with network analyzers to record energy consumption The meters are housed in a separate closet The measured values can be transferred to the existing management system Econ via a data logger The following outlets receive a separate current measurement Sub distributor AV sub distributor SV RLT SV 2 x refrigeration SV installation devices The usual dimensions of 0 3 m and 1 1 m above FFB are chosen as installation heights For the office the workstations were equipped according to a list of equipment from the AG Schuko sockets and RJ45 sockets are arranged in a parapet duct below the outer window All sockets 230 V 400 V RJ45 and fixed connections required for the kitchen and serving area were specified by IB Beck In consultation with the user further connections were provided The planning of the installation devices in the cooling and freezer rooms is not part of this planning but is done by the kitchen planning The supply lines for the installation are provided by Eproplan in accordance with IBBeck s specifications For this purpose a corresponding cable list is passed on by IB Beck An emergency call according to DIN VDE 0834 is planned for the disabled toilet The emergency call is displayed at the gate of the hospital The control for the electric external blinds is part of this planning The motor control unit must be integrated in the control cabinet An on site control point for overriding the automatic mode is provided for the individual rooms Cable routing systems When routing the main cable routes and their dimensions a distinction is made between avoiding EMC impairments with regard to spatially separated routing in accordance with DIN VDE 0800 174 2 and 0100 710 in low voltage without functional integrity AV low voltage with functional integrity SV Data communication fire alarm systems By using a heating cooling ceiling in the guest room the cable installation can be integrated into the ceiling panels or covered by them To the island area with cash register and merchandise the pipes are routed below the floor in empty pipes laid in the screed An a P Installation All other rooms are u P installed The introduction of media channels into the building main building and cafeteria must be partitioned according to fire resistance class S90 Cables and wires Cabling is carried out using halogen free cables The dimension for 0 4 kV cable takes into account the DIN VDE 0298 4 DIN VDE 0100 520 supplementary sheet 2 5 1 Maximum voltage drop behind the measuring device to the consumer system 3 According to DIN VDE 0100 560 DIN VDE 0100 710 and MLAR 5 2 2 cables and wires are for safety lighting systems up to the fire compartment in which the corresponding lights are installed fire alarm systems except for cables that are installed in monitored rooms and ring lines with separately laid outgoing and return lines Systems for alarming the persons concerned and giving instructions that are in the fire caseTime limit for receipt of tenders or requests to participate Date 20 07 2020 Local time 10 45 Disclaimer The above text is machine translated For accurate information kindly refer the original document
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 30889227
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.