Contract Notice Mechanical Stirrers12 Fold Parallel Bioreactor SystemDescription Pc As Control Unit With Uninterruptible Power Supply For The Parallel Operation Of 12 Bioreactors The Computer Should Have The Highest Possible Storage Capacity Sufficient Memory And Processor For Easy Use Of The Software Software For Individual Or Parallel Control Of The 12 Bioreactors As Well As For Recording Control And Archiving Of Process Data Bioreactors Should Be Made Of Glass And Autoclavable Racks For Transport And Autoclaving Process Working Volume At Least 60 Ml Not More Than 300 Ml Ph Po2 Sensors From Hamilton Foam And Level Sensors Temperature Sensors Bioreactors Must Be Able To Be Operated And Controlled Independently Of One Another With Respect To Ph Po2 Stirrer Speed Gas Mixture Compressed Air O2 Co2 And N2 And Temperature Ph Should Be Individually Adjustable And Adjustable Between 2 9 Configurable And Nestable Po2 Cascades For Speed Of Rotation Of The Stirrer O2 N2 Concentration Gassing Rate Gas Mixing Station For Operation With Compressed Air And Metered Pure Oxygen Fumigation By L Sparger With Supply Air Filter Level Foam Sensors Individual Measurement Control And Adjustment Of The Sensitivity For The 12 Bioreactors Stirrer With Two 6 Blade Disc Stirrers With Directly Coupled Overhead Drive For Viscous Solutions Display Of The Current Torque In The Software Stirring Speed Min Up To 2 000 Rpm Display Of The Current Torque For Each Bioreactor The Temperature Should Be Individually Adjustable Minimum Temperature Range Of 15Oc To 55Oc Exhaust Air Cooling And Heating Cooling Of The Bioreactors Must Be Anhydrous For Space And Safety Reasons Each Bioreactor Should Have At Least Four Sterile Ports For Fluid Addition Base Acid Antifoam Feed Inoculum Extension By 2 Sterile Ports Must Be Possible For Each Bioreactor At Least 4 Independent Freely Assignable Peristaltic Pumps With A Minimum Pump Rate Range Of 0 005 Ml Ml 7 Ml Min Without Replacement Of Pump Heads Tubing And Priming Bottles Should Be Included In The Offer Possibility Of Sterile Sampling During The Cultivation Process Cleaning In Place Cip Function For Dry Cleaning And Sterilization Of Media And Pump Tubing Integration Retrofit Of Third Party Online Analyzers Should Be Possible Software Features Export In Csv Format Ready To Use Routines For Simultaneous Calibration Of Po2 And Ph Sensors Flexible Programming For Automation Of Process Flows Custom Control Loops With Configurable Input Values Later Integration Of Third Party Devices Via Analogue Input Modbus Or Opc Must Be Possible Installation Device Acceptance And Full On Site User Training For The Handling Of The System And The Software The Entire System Has To Be Able To Be Maintained And Cleaned Independently By The User As Far As Possible For Which Purpose Suitable Sources Eg Instructions Or Videos Or Training Must Be Provided Customer Service And Technical Support Must Be Available In Germany And Reachable By Telephone During Normal Business Hours In Germany All Required Specifications Must Be Clearly Visible In The Offer Documents With The Offer The Site Preparation For The System Must Be Submitted Delivery Until Week 48 Free Point Of Usethe Legal Warranty Starts Only After Installation With The Acceptance Of The Device Time Limit For Receipt Of Tenders Or Requests To Participate Date 09 08 2019 Local Time 12 00 Disclaimer The Above Text Is Machine Translated For Accurate Information Kindly Refer The Original Document
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 21243172
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.