Tenders Are Invited For Local Bidding Public Bidding Announcement For The Procurement Project Of Rehabilitation Equipment For Disabled People In Wuyuan County Disabled Persons Rehabilitation Center Budget Amount 117 6 Million Rmb Technical Parameters 1 Power Ac220v Frequency 50Hz 2 Rated Input Power 120Va 3 Control Method Handle Jog Control 4 Bed Height 550Mm Tolerance 50Mm 5 Dimensions 2100Mm 900Mm 550Mm Tolerance 50Mm 6 Bed Surface Erect Angle 0 90 Adjustable Tolerance 5 7 The Pedal Up And Down Adjustment Angle Dorsiflexion 0 20 Kneeling 0 30 Tolerance 3 Pedal Adjusting Angle Inside And Outside The Board 0 30 Inversion 0 30 In Outer Turn Tolerance 3 8 Composition Bed Frame Bed Surface Handrail Table Top Fixed Belt Foot Pedal Hand Control Device Composition 9 Rated Load On The Bed Surface 125Kg Tolerance 10Kg 10 The Pedals Can Be Adjusted Up And Down And Left And Right Angles Rehabilitation Training According To The Angle Of The Ankle Joints Makes The Patients Have More Comfortable Feet 11 Equipped With 4 Casters Through The Pedal Four Linkage Mechanism Control The Lifting Of The Casters To Facilitate The Movement Of Equipment 12 Equipped With A Hand Held Switch Easy To Lift Control Of The Bed Surface 13 The Bed Surface Is Made Of High Quality Medical Special Leather Environmental Protection Moisture Proof Anti Bacterial And Fireproof Materials 14 Equipped With Legs To Adjust The Feet To Facilitate The Adjustment Of The Bed 15 Handrail Table Top Can Be Adjusted Up And Down Convenient For Patients To Use Specification Cm 40 40 102 Quality 14 0Kg Gymnastics Bar Specifications Cm F2 8 100 Number Of Gymnastics Bars 5 Throwing Bar Diameter Cm Not Less Than F25 Gymnastics 4 Sticks Lateral Maximum Load N 100Uses Improve The Range Of Upper Limb Activities Improve The Ability Of Limb Coordination Control And Balance By Performing Exercises With Rods And Throwing Balls I Cognitive Disability Rehabilitation Assessment Training System V1 0 Creation Purpose Main Functions And Technical Features All Tests Of This System Are Controlled By Computer Programs Computerized Instructions Operations Tests Results Storage And Analysis Are Integrated Test Results Are Obtained Immediately After The Test Is Completed So That The Information Is Promptly Fed Back Compared With Traditional Manual Detection Computer Aided Cognitive Function Detection Is Accurate Objective Fast And Simple The Design Of This System Is A Preliminary Exploration Of The Measurement Form Of The Neuropsychological Scale From Manual Measurement To Computer Aided Detection The System Undertakes The Diagnostic Part And Contains Training On Orientation Organization Memory Concentration Reasoning And Calculation Of Six Abilities The Scope Of The Design Is Also Wide Including Cognitive Impairment Caused By Brain Damage Mild Affective Disorder Or Impaired Brain Development In Children The Rehabilitation Aspect Mainly Focuses On Structural Organization Ability Orientation Ability Concentration Ability Memory Ability Calculation Ability And Reasoning Ability The Rehabilitation Part Is Divided Into Three Difficulty Gradients And Each Difficulty Gradient Is Divided Into Three Aspects Structural Organization Competence Spatial Understanding Spatial Synthesis Orientation Judgment And Orientation Ability Time Orientation Location Orientation Character Orientation Focus Ability Visual Focus Auditory Focus Connected Game Memory Ability Image Memory Logical Memory Motion Memory Computing Ability Direct Calculation Indirect Computing Creative Computing Reasoning Ability Order Reasoning Image Reasoning Event Reasoning 2 Technical Parameters Cognitive Impairment Rehabilitation Evaluation Training System Is Applicable To Qualified Personal Computer Computer Host Products With The Following Configurations The Personal Computer Host Can Be Configured To Meet Customer Requirements Second The Main Technical Functions 1 Medical Records Management Includes Case Registration Entry Medical Record Query Modification Deletion And So On 2 Diagnosis Of The Condition According To The Diagnosis Different Degrees Of Disease Are Judged 3 Orientation Ability Time Place Person 4 Focus On Ability Number Order Catch Connection Comprehensive Focus 5 Structural Ability Space Understanding Spatial Synthesis Spatial Structure 6 Computational Power Direct Indirect And Creative Operations 7 Memory Visual Auditory Logical And Athletic 8 Reasoning Ability Order Event Structure Memory Comparison Spatial Reasoning Similarity Training Sound Perception Thing Classification Semantic Classification 9 Voice Training 10 The Topic And The Platform For The Problem 11 Rehabilitation Platform Language Ability Pairing Memory Attention Classification Observation Concentration Arithmetic Symbols Addition Subtraction Multiplication Division Computational Power Visual Memory Specification Cm 5 195 100 95 Operation Panel 50 40 Length Width Cm Rear Operation Panel 100 35 Length Width Cm Operation Panel Adjustment Range 45Cm 80Cm Uses Improve Finger Finger Function Improve Eye Hand Coordination Function Exercise Capacity Of Patients Perceived Ability To Identify And Brain Patterns And To The Stability Of The Upper Limb Training Coordination Improve The Limb Activities Of Daily Living Components The Upper Limb Coordination Function Training Device Finger Fingerboard Fingerboard Arc Iron Stick Insert Wood Insert Ferrule Vertical Geometric Insert Cognitive Graphics Insert Simulation Work Tool Upper Screw Upper Nut Magnetic Button One Treatment Mode Kneading Beating Pressing Combination Two Output Function 1 Intermediate Frequency Intermediate Frequency Carrier Frequency 2000 5 Hz Modulation Frequency 1 440Hz Pulse Amplitude 50V 10 Pulse Width 500s 5 2 Hyperthermia 25V Extra Low Safety Voltage 5 Kinds Of Strength Can Choose 60 Degrees Celsius Over Temperature Protection3 Magnetic Therapy The Magnetic Field Strength Of The Pad Is 2000 3000 Gauss The Low Frequency Alternating Weak Electromagnetic Field And The Rare Earth Strong Permanent Magnet Have The Same Magnetic Field 3 Output Intensity Independent Output Of Each Instrument At 500 Ohm Load Current The Valid Value Does Not Exceed 100Ma The Output Intensity Of The Therapeutic Device Is Adjusted The Range Of Electrotherapy Is 0 To 248 The Long Press Is 3 Seconds The 5 Can Be Entered Into The 1 Function The Thermal Therapy Range Is 0 To 5 When The Electrotherapy Is Adjusted The Output Intensity Increases With The Increase Of The Number Of Stages Continuously Adjustable And No More Than 1Ma Or 1V Per Stage V Treatment Time 0Min 100Min Countdown Calculation There Are Voice Prompts For Channels And Categories After Long Press Long Press For 3 Seconds To 5 Into 1 Function Allowable Error 10 6 Normal Working Conditions 1 Ambient Temperature 5 C 40 C 2 Relative Humidity 15 85 3 Atmospheric Pressure 700Hpa 1060Hpa 4 Use Power Supply Ac220v 22V 50Hz 1Hz 7 Display Mode 8 Inch Large Screen Lcd Display Independent Display And Independent Operation Keyboard User Friendly Operation Convenient Design Built In Core Components Safe And Durable 9 Output Channel Can Simultaneously Treat Two People Independent Operation Interface Mutual Do Not Interfere With Ten Computer Software Copyright Registration Certificate Through The National Copyright Administration Of Peoples Republic Of China Issued The Certificates And Utility Model Patents Xi Indications Applicable To Cervical Spondylosis Frozen Shoulder Lumbar Muscle Strain Rheumatoid Arthritis Relieving Pain Improve Blood Circulation Promote Inflammation Dissipation Effect An Output Waveform Having A Wide Wavelength Ii Wave The Small Wave I Wave Two Waveforms A Total Of 10 Kinds Of Frequencies 0 5Hz Interval Frequency Range 0Hz 5Hz 1 Waveform Ii When The Pulse Width Is 10Ms 500O The Output Peak Value Is 32V The Output Pulse Frequency Is 0 5 5Hz 2 Waveform I Pulse Width Is 1Ms Modulation Wave Width Is 10Ms Maximum Output Peak Value When Load Is 3K 45V When Load Is 500O Maximum Output Peak Value 32V Carrier Pulse Frequency Is 500Hz Modulation Wave Frequency Is 0 5 Hz 5Hz Second Output Intensity Independent Output Of Each Instrument When 500O Load Impedance The Current Peak Value Is 80Ma 30 When Measuring Under Open Circuit Condition The Output Peak Voltage Does Not Exceed 500V Intensity Class 0 200 Intermittent Adjustment Each Stage Increment Does Not Exceed 1Ma Or 1V Three Treatment Time 0Min 90Min 10 Independently Adjustable Four Normal Working Conditions Ambient Temperature 5 C 40 C Relative Humidity 30 85 Atmospheric Pressure 700Hpa 1060Hpa Use Power Ac220v 10 50Hz 10 Five Display Mode 8 Inch Large Screen Touch Screen Operation Independent Display And Independent Operation Interface User Friendly Operation Six The Number Of Output Channels Independent 2 Channels Eight Product Requirements Passed Is09001 Quality System Certification And China Medical Device Quality Certification Center Cmd Certification Nine Indications Improve Disuse Muscle Atrophy And Promote Peripheral Nerve Repair Technical Parameters 1 Size 420 Mm 360Mm 230Mm Tolerance 10 2 Rated Input Power 100Va 3 Dual Channel Output Digital Display 3 Treatment Mode Massage And Import 4 Output Channel Dual Channel 5 If Carrier Waveform Sine Wave 6 Modulated Wave Waveform Square Wave 7 Amplitude Modulation 50 Tolerance 10 8 Carrier Frequency 2Khz Tolerance 10 9 Modulated Wave Frequency 75Hz Tolerance 10 11 Output Intensity 0 To 99 Adjustable12 Timing Range 1 60 Min Continuously Adjustable The Default Value Of The Boot Is 25Min Tolerance 10S 13 Scope Of Application It Is Suitable For Auxiliary Treatment Of Pain Caused By Chronic Soft Tissue Injury 14 Photoelectric Rotary Encoder Pressing And Rotating Setting Parameters Are Quick And Convenient One Button Shuttle 15 Output Protection Function It Has Output Short Circuit Protection And The Treatment Instrument Has Output Blocking Protection Function 16 With Medical Device Registration Certificate 1 With Magnetic Therapy Five Magnetic Head Stimulation Function Magnetic Cap Five Treatment Body Light And No Weight Bearing 2 Magnetic Field Frequency 50Hz 2 3 Intensity I Gear 3 10Mt Ii Gear 11 25Mt 4 Amplitude 4Th Gear 0 Gear 0 1 Gear 10V 20 2 Gear 16V 20 3 Files 27V 20 5 Vibration Frequency 0 10Hz Adjustable Step Size 1Hz 6 Nine Treatment Modes Frequency Intensity Time Can Be Adjusted For Different Disease Selection Mode Can Be Personalized According To Patient Fitness Adjustment 7 Time 1 99Min Boot Default 20 Minutes Display The Remaining Treatment Time Countdown Alarm Function 8 Display Mode 10 4 Large Screen Touch Screen With Lock Screen Function 9 Luxury Stroller Structure Can Treat Two Patients At The Same Time Independent Operation Interface Does Not Interfere With Each Other Easy To Move The Wheel Can Be Fixed Convenient For Patient Treatment 10 The Product Has Passed Is09001 Iso13485 Quality System Certification And China Medical Device Quality Certification Center Cmd Certification Technical Features 1 Through The Microcomputer To Set The Traction Time And Traction And Other Treatment Parameters 4 Electronic Sensors To Detect Traction Traction Can Be Compensated At Any Time 5 With 8 Traction Modes Sustainable Intermittent Or Stepped Traction 6 With A Retreat Key And Patient Hold The Retract Switch To Ensure Safety7 Sitting Cervical Traction Device Cervical Traction And Lumbar Traction Can Be Performed Simultaneously 10 The Medical Record System Can Store And Read 20 Groups Of Technical Parameters Power Source 220V 50Hz Power 240W Lumbar Traction Force 0 99 Kg Cervical Traction Force 0 30 Kg Traction Total Time 0 60 Minutes Continuous Traction Time 0 9 Minutes Intermittent Time 0 90 Seconds Step Traction Time 5 Seconds Lumbar Traction Stroke Upward 0 100 Down 0 150 Mm Cervical Traction Stroke 0 300 Mm Traction Speed Less Than 15 Mm Sec Bed Height 560 Mm Volume Length Width Height 2400 600 2120 Mm Technical Features 1 Through The Microcomputer To Set The Traction Time And Traction And Other Treatment Parameters 3 Digital Tube Display Traction Time And Traction 4 Electronic Sensor Detects Traction Traction Can Be Compensated At Any Time 5 There Are 8 Traction Modes Sustainable Intermittent Or Stepped Traction 6 With Emergency Button And Patient Hand Held Switch Safety Is Guaranteed 9 The Medical Record System Can Be Stored And Read Take 20 Sets Of Case Technical Parameters Specification 5Cm Power 220V 50Hz Power 120WTraction 0 99 Kg Total Traction Time 0 60 Minutes Continuous Traction Time 0 9 Minutes Intermittent Time 0 90 Seconds Step Traction Time 5 Seconds Traction Stroke Up 0 100 Down 0 150 Mm Traction Speed Less Than 15 Mm Sec Bed Height 560 Mm Volume Length Width Height 2400 600 670 Mm Size Cm 5 100 15 50 Use Play The Imagination Of Children Cultivate Their Own Hands And Ability Technical Parameters 1 Early Language Assessment And Training System Is Used To Detect Process Edit And Store Voice Signals Including Keyboard Input Signal Input Editing Amplitude Control Signal Output Storage And Printing Functions 2 The System Provides An Assessment Of Early Childhood Language Proficiency Assessing Aspects Related To Words Phrases Sentences And Essays The System Designs Words Phrases Sentences Essays And Training At Various Stages According To The Rules Of Childrens Language Development It Can Perform Unconscious Communication Of Childrens Wake Up Training Conscious Communication Training And Short Sentences And Short Term Expression Communication Training The Training Content Is Divided Into A Number Of Topics Containing A Large Number Of Vocabulary Sentences And Essay Materials To Facilitate Personalized Teaching And Training For Children 3 The System Consists Of Five Modules Including System Introduction Student Management Language Assessment Language Training And Ecological Teaching Platform 4 System Introduction To The Development Of Speech Vocabulary Development Lexical Semantic Development Sentence Grammar Development Development Of Comparative Sentences Development Of Words Development Of Words Development Of Words The Development Of The Structural Sentence Is Explained In Detail In The 10 Childrens Language Development Process And Age Group 5 Can Modify Delete Print Re Find Statistics Help The User Data Can Compare The Results Of Multiple Evaluations Of The Same Trainee Before And After The Analysis Display The Histogram Track The Training Effect 6 It Can Realize Two Evaluation Forms Stage Evaluation And Real Time Training Evaluation It Can Evaluate The Various Stages Of Words Phrases Sentences And Essays According To The Evaluation Results The Goal Of Early Language Intervention The Specific Means Of Intervention And The Provision Of Multiple Interventions Can Be Provided So That Students Can Learn From The Awakening Training Of Unconscious Communication And Conscious Communication Training Until They Can Exchange Expressions Of Short Sentences And Short Sentences 7 According To And Follow The Laws And Theories Of Language Development Select A Large Number Of Important And Key Basic Words Phrases Sentences And Essays At Different Stages Of Language Development Including Word Learning Phrase Learning Sentence Learning Essay Learning Nursery Rhymes The Yin Yue Hall Trains In Six Training Stages The Childrens Training Interest Is Stimulated By The Identification Of Different Types Of Questions Such As Recognition Recognition Language Prosody Measurement Situational Application And Sentence Synthesis Application 8 Eco Teaching Platform Open Self Editing Teaching Platform Teachers Can Design Edit And Build Large Scale Training Questions Training Voice Pictures Videos Rewards According To The Actual Level And Teaching Needs Of Different Trainees Etc Carry Out Intensive Individualized Training At Each Stage Make The Training Of The Trainees More Targeted Thus Improving The Effectiveness And Efficiency Of The Training 9 The Scope Of Application For Language Development Retardation Mental Retardation Autism Cerebral Palsy Down Syndrome And Other Language Disorders Specification Cm 43 43 10 Big Ball 6 3 Medium Ball 3 Small Steel Ball 0 8 Large Wood Square 9 6 9 6 3 6 Medium Wood 3 5 3 5 3 5 Small Wood Square 1 5 1 5 1 5 Wood Garden Plate 3 5 1 Human Leather Cloth 9 7 Metal Garden Piece 2 Inner Hole 0 5 0 4 Steel Bar 0 4 6 Mass 5 0Kg Use Objectively Detect Upper Limb Ability And Movement Speed Judge Upper Limb Function Restricted DegreeVisual Type E Check Distance 2 5M Inspection Range From 3 7 To 4 7 Vision Record Five Points Record Decimal Record Logmar Eye Chart Light Box Size 76 57 3Cm Eye Chart Total 14 Lines Of Visual Standard From Large To Small The Apparent Growth Rate Of The Adjacent Two Rows Is 1 2589 And The Difference Of The Size Of The Visual Markers Every 10 Lines Is 10 Times Which Can Flexibly Measure The Distance The Visual Acuity Chart Is The Automatic Detection Of The Distance After The Variable Distance Detection And The Automatic Report Inspection Standard Visual Value Technical Parameters 1 Power Ac220v 50Hz Dc24v 2 Rated Input Power 190Va 3 The Maximum Lifting Weight 200Kg Tolerance 10Kg 4 Size Length Width Height Mm 1970 660 570 870 Tolerance 3 5 Lifting Function The Bed Surface Lifting Stroke Of The Medical Bed Is Continuously Adjustable From 0 To 300Mm And The Tolerance Is 30Mm 6 Head Section Surface Function Relative Horizontal Plane Adjustment Angle 20 30 Continuously Adjustable Tolerance 3 7 Waist And Chest Section Function Relative Horizontal Plane Adjustment Angle 0 25 Continuously Adjustable Tolerance 3 8 Lower Body Section Function Relative Horizontal Plane Adjustment Angle 25 40 Continuously Adjustable Tolerance 3 10 Equipped With A Bed Leg Adjustment Screw Regardless Of Any Ground Can Be Adjusted To Multi Position Medical Treatment Bed Surface 11 With Patient Breathing Holes And Shoulder Holes 12 Using High Quality Gas Springs Durable Specification Cm 45 45 45 58 Lifting Range 45 58 Quality 7 0Kg Use Therapist Can Move The Seat When The Patient Is Treated Manually 1 Training Site Biceps Triceps Diaphragm Diaphragm Forearm Muscles 2 Training Effect 2 1 Used To Strengthen The Elbow Joint Flexion And Extension Related Muscle Training 2 2 Shoulder Joints Upper Limb Joints Tendon Strengthening And Activation 2 3 Strengthen The Mobility Of The Hand Carrying Items And Reduce The Risk Of Strain Injury Of Muscle Groups Such As Biceps 3 Adjusting Gear Position 10 Way Two Way Resistance Adjustment 4 Outline Structure High Hardness Steel Structure 5 Dimensions 5Cm 930Mm 750Mm 900Mm 6 Product Weight 34 1 10 Kg First The Output Waveform With Wide Wave Ii Wave Fine Wave I Wave Two Waveforms A Total Of 10 Kinds Of Frequency Interval 0 5Hz Frequency Range 0Hz 5Hz 1 Waveform Ii Pulse Width Is 10Ms 500O When The Output Peak Frequency Is 32V The Output Pulse Frequency Is 0 5 5Hz 2 Waveform I Pulse Width Is 1Ms Modulation Wave Width Is 10Ms Maximum Output Peak Value When Load Is 3K 45V Maximum Output Peak Value When Load Is 500O 32V The Carrier Pulse Frequency Is 500Hz And The Modulation Wave Frequency Is 0 5Hz 5Hz 2 Output Intensity Independent Output Of Each Instrument When 500O Load Impedance The Current Peak Value Is 80Ma 30 When Measuring Under Open Circuit Conditions The Output Peak Voltage Does Not Exceed 500V Strength Level 0 200 Level Intermittent Adjustment Each Stage Increment Does Not Exceed 1Ma Or 1V 3 Treatment Time 0Min 90Min 10 Independently Adjustable 4 Normal Working Condition Ambient Temperature 5 C 40 C Relative Humidity 30 85 Atmospheric Pressure 700Hpa 1060Hpa Use Power Ac220v 10 50Hz 10 Five Display Mode 9 7 Inch Large Screen Touch Screen Display Independent Display And Independent Operation Of The Keyboard User Friendly Make Six Luxury Cabinet Structure Easy To Move Built In Imported Components Safe And Durable Seven The Number Of Output Channels Can Simultaneously Treat Four People Independent Operation Interface Do Not Interfere With Each Other Indications Improve Disuse Muscle Atrophy And Promote Peripheral Nerve Repair 1 Output Waveform A B Two Sets Of Output Are Two Way Asymmetric Pulse 2 Pulse Period 1S 2S Continuously Adjustable Step Size 0 1S Tolerance 15 3 Pulse Width 0 1Ms 0 5Ms Continuously Adjustable Step Length 0 1Ms Tolerance 30 4 Output Intensity The Output Of The Therapeutic Instrument A And B Is Continuously Adjustable From 0 To 99 And The Maximum Output Pulse Current Should Be 100Ma 5 Time The Output Waveform Of The Therapeutic Instrument Group A Is In The Front And The Output Waveform Of The B Group Is Delayed Relative To The A Group The Delay Time T1 Is Continuously Adjustable From 0 1S To 1 5S The Step Length Is 0 1S And The Tolerance Is 15 Timing Function 0Min 99Min Adjustable Maximum Error Is 2Min 7 Output Pulse Power When The Maximum Output Of The Therapy Device Is The Smallest When The Pulse Width Is Minimum Under The Condition Of 500O Load The Power Of Each Pulse Must Be Not Less Than 7c 8 Output Pulse Energy The Output Of The Therapeutic Device Is 500O And The Energy Of Each Pulse Must Not More Than 300Mj When Measuring Under Open Circuit Conditions The Maximum Peak Value Must Be No More Than 500V 9 Output Load Impedance 500O 10 10 Product Features 1 Luxury Stroller Structure Using Ultra Quiet Universal Wheel Wheel Can Be Fixed 2 Using A 10 4 Inch High Definition Color Lcd Display To Display A Variety Of Treatment Information At A Glance Intelligent Menu Operation Easy To Use 3 Microcomputer Control Button Operation 4 Stored 6 Groups Of Prescriptions And Can Make A Prescription 5 10 Prescriptions Can Be Customized And Can Be Modified At Any Time 6 The Current Intensity Of The Two Outputs Of A And B Can Be Adjusted Synchronously Or Asynchronously 7 Two Way Intelligent Output Which Can Treat Two People At The Same Time Or One Person Multi Site Treatment 8 Combine The Pulse Combination Waveform With Bioinformatics Simulation Technology And Computer Software Technology And Alternately Output Two Sets Of Pulses To Stimulate The Diaphragm And Antagonist Muscle Of The Patient 11 Indications Stimulate The Diaphragm And Antagonist Muscle So That The Two Alternately Shrink Treat Spastic Paralysis And Carry Out Electrical Stimulation Electric Gymnastics 1 Scope Of Application 1 1 For Muscle Dysfunction Caused By Strain And Chronic Pain 1 2 Rehabilitation Of Soft Tissue Injuries Such As Sprains And Strains 1 3 For Muscles With Shorter Or Atrophic Length Effectively Promote Balance Of Muscle Strength And Restore Correct Posture 1 4 Treatment And Relaxation Of Whole Body Like Or Partial Muscle Tension After Training Effectively Relieve The Accumulation Of Lactic Acid And The Prevention Of Injury After Training 2 Performance Parameters 2 1 Low Voltage Power Supply Mode Is Adopted To Ensure The Safety During Use 2 3 Is A Mechanical Shock Treatment Equipment The Frequency Is Adjustable From The Frequency Of 15 60Hz 2 4 When The Output Frequency Is Changed The Impact Force Of The Equipment Is Constant Ensure The Depth And Efficacy Of Treatment 2 5 Kinds Of Treatment Heads To Choose From According To Clinical Needs Combined With Treatment Site And Intensity 2 6 Treatment Depth Up To 20 60Mm Both Surface And Deep Tissue Can Be Treated 2 7 Equipment Weight Is 2 5Kg The Overall Center Of Gravity Is In The Head Part Easy To Operate 2 825 C Room Temperature The Equipment Continuous Working Temperature Does Not Operate 41 C 2 9 Treatment Handle Is Equipped With A Rubber Holster For Easy Grip 2 10 Power Output Line And The Host Connection Is Firm And Reliable The Maximum Withstand The Pulling Force Is Not Less Than 5Kg 3 Scope Of Application The Bilateral Mastoid Area Is Stimulated By Current To Improve Blood Circulation In The Brain The Limb Is Stimulated By Current And It Is Used For Electrical Stimulation Of Nerves And Muscles 4 Performance Parameters 4 1 One Channel Headband Electrical Stimulation With Two Channel Limb Neuromuscular Electrical Stimulation Can Simultaneously Treat The Head And Limbs 4 25 7 Inch Lcd Touch Screen Display Intuitive Display Easy To Operate 4 3 Touch Screen One Button Shuttle Easy To Operate Diversified 4 4 Headband Electric Stimulation Device Outputs Human Body Simulation Bio Current Promotes Blood Circulation To Normal In The Brain 4 5 Electric Stimulation Headband More Convenient To Wear More Precise Treatment 4 6 Headband Electric Stimulation Device Pulse Width 400Us 120Us Pulse Period 18Ms 46Ms Frequency 21Hz 56Hz 4 7 Head Hoop Electrical Stimulation Device Output Intensity 0Ma 30Ma Adjustable 4 88 Built In Limb Neuromuscular Electrical Stimulation Prescription To Meet The Treatment Needs Of Patients With Different Physical Dysfunction 4 9 Limb Electricity The Stimulation Device Outputs A Specific Pulse Modulation Wave And There Is No Risk Of Electrocautery Burn 4 10 The Limb Neuromuscular Electrical Stimulation Device Has A Pulse Frequency Of 4000 400 Hz And A Modulation Frequency In The Range Of 0 03 To 1 2 Hz 4 11 Limb Neuromuscular Electrical Stimulation Device Has An Output Intensity Of 0 Ma To 100 Ma 4 12 1 99Min Treatment Time Continuously Adjustable Step Length 1Min 4 13 Constant Current Output To Ensure The Safety Of The Treatment Full Effective Treatment Can Be Quantified 4 14 Open Circuit Alarm To Ensure Treatment Safety 1 Scope Of Adaptation Applicable To The Adjuvant Treatment Of Swallowing Dysfunction Caused By Neuromuscular Injury 2 Performance Parameters 2 1 There Are Two Types Of Electrotherapy Output Modes Constant Current And Constant Voltage 2 2 Dual Channel Output Each Channel Can Set The Treatment Parameters Independently 2 3 Output Intensity Adjustable From 0Ma To 25Ma Or 0V To 25Vp P Step Size 0 1Ma Or 0 1V 2 4 Pulse Frequency 20Hz 100Hz Adjustable Step Size 1Hz 2 5 Pulse Width 100s 400s Adjustable Step Size 10s 2 6 The Pulse Waveform Is A Bidirectional Symmetric Wave With A Positive And Negative Pulse Interval Of 100 s 2 7 Pulse Rise Time And Fall Time Adjustable From 1S To 10S Step Size 1S 2 8 Pulse Maintenance Time Adjustable From 1S To 55S Step Size 1S 2 9 Pulse Power Off Time 3S 75S Adjustable Step Size 1S 2 10 Treatment Time 1 99Min Adjustable Step Length 1Min 2 11 Fixed Electrodes Have Three Treatment Modes 2 13 Built In Electrode Placement Diagram For Easy Use 2 14 The Electrical Stimulation Handle Is Operated By The Therapist To Control The Duration Of The Current Output According To The Treatment Demand 2 15 Touch Screen One Button Shuttle Easy To Operate 2 16 Open Circuit Alarm Prompts Over Current Protection To Ensure Treatment Safety Disclaimer The Above Text Is Machine Translated For Accurate Information Kindly Refer The Original Document
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 19745337
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.