Contract Notice Installation Services Of Electricity Control EquipmentModernization And Extension Of The School Building Gymnasium PlauenDescription 1 General Construction Of Automation System Based On Data Communication Standard Bacnet According Todin En 16484 5 Taking Into Account The Amev Recommendations 2017 2 Existing Building To 1 150 Field Devices Including Valves With Drives 485 Physical Data Points 120 Communicative Data Points 160 Communicative Data Points Fire Damper Ring Bus System Data Communication Interface Bacnet Ip For Connection Of 2 Central Ventilation Units Data Communication Interface Modbus Rtu Via Eia 485 For Connection Of Thermal Management System For 4 Gas Condensing Boilers Data Communication Interface Meter Bus M Bus For Recording Consumption Values Meter Connection Installation Of 4 Switchgear Msr Ga As Information Centers Isp With 12 Standard Fields Installation Of 150 M Cable Routes Within Technical Centers And Attic Rooms Laying 14 400 M Of Cables Lines Halogen Free Sheath Fm And Data Cables Lines Fire Damper Ring Bus System For Control And Monitoring Of Approx 45 Motorized Fire Dampers With Data Communication Interface Bacnet Ip Installation Of A Control Unit Mbe With Building Management Software Installed On A 22 Lcd Touch Panel Pc Installed In The Control Cabinet Front Integration Of The Automation Stations In The Home Network No Active Network Infrastructure Components Set Up System Access From Provided Workstation Pc To Building Management Software Via Home Network 3 Extension New East And West To 2 20 Field Devices Including Valves With Drives 35 Physical Data Points 50 Communicative Data Points 10 Communicative Data Points Fire Damper Ring Bus System Data Communication Interface Bacnet Ip For Connection To A Central Ventilation Unit Data Communication Interface Bacnet Ms Tp For The Connection Of 2 Room Control Units Data Communication Interface Meter Bus M Bus For Recording Consumption Values Meter Connection Extension Of 2 Switchgear Msr Ga As Information Centers Isp In The Existing Building To 1 Laying 1 000 M Of Cables Lines Halogen Free Sheath Fm And Data Cables Lines Extension Of The Fire Damper Ring Bus System In The Existing Building For Control And Monitoring Of Approx 5 Motorized Fire Dampers With Data Communication Interface Bacnet Ip Handover Of The Original Calculation On Special Request Of The Awarding Authoritythe Commissioning Of The Maintenance Contract Is Carried Out By The Property Management Agency At The Same Time As The Commissioning Of The Installation In The Bid Evaluation The Prices Quoted In The Maintenance Offers Are Taken Into Account For An Intended Term Of 4 Years Without Application Of A Present Value Factor Time Limit For Receipt Of Tenders Or Requests To Participate Date 18 02 2019 Local Time 15 00 Disclaimer The Above Text Is Machine Translated For Accurate Information Kindly Refer The Original Document
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 18416527
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.